  • WORTHINGTON 6S NON CONDENSING SPARE ROTOR @ W1E1

    No price - La Porte, TX
    • Manufacturer: Worthington

    spare rotor @ w1e1; 730 f. inlet; trip speed 6630; max cont. rpm 6200; 367 f. exhaust temp; u-12475;

  • WESTINGHOUSE EH-125 NON-CONDENSING STARTER TURBINE

    No price - La Porte, TX
    • Manufacturer: Westinghouse

    westinghouse starter turbine; re-built in 1996; 750 deg. f.; 4810 rpm; trip rpm 5400; excellent condition; never put in service;

  • WESTINGHOUSE EH-125 NON-CONDENSING STARTER TURBINE

    No price - La Porte, TX
    • Manufacturer: Westinghouse

    westinghouse starter turbine; 750 deg. f.; 4810 rpm; trip rpm 5400; excellent condition; never put in service; re-built in 1996;

  • TURBODYNE S4 NON-CONDENSING PREVIOUS SERVICE-COOLING TOWER PUMP DRIVE

    No price - La Porte, TX
    • Manufacturer: TURBODYNE

    previous service-cooling tower pump drive; frame s4; inlet 600 psig @ 720 deg. f.; cw rotation from governor end; exhaust 35 psig @ 377 deg. f.; 1st crit speed 3280 rpm; 2nd crit speed 12742 rpm; t...

  • TURBODYNE S4 NON-CONDENSING PREVIOUS SERVICE-COOLING TOWER PUMP DRIVE

    No price - La Porte, TX
    • Manufacturer: TURBODYNE

    previous service-cooling tower pump drive; frame s4; inlet 600 psig @ 720 deg. f.; cw rotation from governor end; exhaust 35 psig @ 377 deg. f.; 1st crit. speed 3280 rpm; trip speed 4850 rpm; max c...

  • SIEMENS G300-2 NON CONDENSING INLET 6" 1500# DOWN

    No price - La Porte, TX
    • Manufacturer: Siemens

    **unused** inlet 6" 1500# down; exh 12" 300# down; ccw rotation 725 deg. f.; steam consumption 66.8 ton/hr @ 4885 hp; the unit can go down to 3190 hp and 6883 rpm and 584 psi exhaust; spare rotor a...

  • ELLIOTT BHPG-3 NON-CONDENSING INLET 580 PSIG @ 700ºF

    No price - La Porte, TX
    • Manufacturer: Elliott

    inlet 580 psig @ 700ºf; discharge 165 psig; hp: 3000 reduced to 2000 in revision 1; stages: 3 rateau; inlet: 6"-600#rf exhaust: 10"-300# ff-up; overhauled 1998; woodward governor: woodward governor...

  • DRESSER RAND 1THB3HB2 NON-CONDENSING POWER GENERATOR STEAM TURBINE

    No price - La Porte, TX
    • Manufacturer: Dresser

    unused dresser rand steam turbine; 15808 kw; inlet steam temperature 749 deg. f.; dresser rand contract number c-33306; connected to a generator item #107122, lufkin gear box item #107124 and inclu...

  • WORTHINGTON 4S NON-CONDENSING CENTRIFUGAL COMPRESSOR 4515 HP @ 9230 RPM

    No price - La Porte, TX
    • Manufacturer: Worthington

    4515 hp @ 9230 rpm; frame #4s; 4 rateau stages; rotation: ccw from governor end; inlet steam 450 psig @ 650 deg f; exhaust 50 psig; 5 automatic venturi steam inlet valves; w/spare rotor # 74520tr;

  • ELLIOTT SBPG4 NON-CONDENSING COMP CENTRIFGAL 590 PSIG STM IN @ 725 DEG F

    No price - La Porte, TX
    • Manufacturer: Elliott

    590 psig stm in @ 725 deg f; 11,586 rpm trip speed; on skid w/compressor;