Top Seller
KOKUSAI #ASC-20S22 HYDRAULIC SHAFT STRAIGHTENING
Location:
Holland, OH
Manufacturer:
Allen presses

Specifications

Condition:
used
Stock number:
51732
Plc:
Allen-Bradley series 5/20
Cpu unit:
IBM compatible computer
Main unit:
1400 W. x 1120 Dp. x 2690 H.
Air supply:
60 psi, 0.3 cfm
Press unit:
Single head hydraulic press, variable position
Press point:
Automatic positioning method, 400 pulses
Floppy drive:
3.5" floppy drive
Power supply:
460 VAC, 3 PH, 60 Hz, 8.2 Hp
Driving motor:
Stepping motor
System weight:
5000 lbs.
Hydraulic unit:
860 W. x 650 Dp. x 1100 H.
Rotation speed:
60 rpm
Angle detection:
Electronic signal from the LVDTs and encoder
Rotation method:
Live-centers clamping center points
Hydraulic pressure:
1,500 psig (110 kg/cm2)
No. of corr. points:
1 or 2 points, depending on the selected model
No. of meas. points:
1 or 2 points
Measurement accuracy:
+/- 2.5 micron (0.0001")
Runout pick-up method:
LVDT sensor with carbide rod

Description

MICROPROCESSOR CONTROLLED SHAFT STRAIGHTENER
SERIAL 6A-0500
NEW 1995
MODEL / SERIES ASC-20S22
JOB MEMORY
MEASURING UNIT SPECIFICATIONS
MEASUREMENT ACCURACY: +/- 2.5 micron (0.0001")
NO. OF MEAS. POINTS: 1 or 2 points
RUNOUT PICK-UP METHOD: LVDT sensor with carbide rod
ROTATION METHOD: Live-centers clamping center points
ROTATION SPEED: 60 rpm
DRIVING MOTOR: Stepping motor
ANGLE DETECTION: Electronic signal from the LVDTs and encoder
PRESS POINT: Automatic positioning method, 400 pulses
per rotation for T.I.R. peak-point
CORRECTION UNIT SPECIFICATIONS
NO. OF CORR. POINTS: 1 or 2 points, depending on the selected model
PRESS UNIT: Single head hydraulic press, variable position
PRESS HEAD POSITIONING METHOD: Ballscrew with AC motor drive and proximity switch position detection
CONTROL UNIT SPECIFICATIONS
CPU UNIT: IBM compatible computer
PLC: Allen-Bradley series 5/20
FLOPPY DRIVE: 3.5" floppy drive
STATISTICAL ANALYSIS
1. Total number of shafts processed
2. Number of Good shafts
3. Number of Reject shafts
4. Percentage of Good shafts
5. Max. runout for each measurement point after correction
6. Min. runout for each measurement point after correction
7. Mean value of runout, before corr., for each meas. point
8. Mean value of runout, after corr., for each meas. point
9. Standard deviation for each measurement point
10. CP value for each measurement point
GENERAL SPECIFICATIONS
POWER SUPPLY: 460 VAC, 3 PH, 60 Hz, 8.2 Hp
AIR SUPPLY: 60 psi, 0.3 cfm
HYDRAULIC PRESSURE: 1,500 psig (110 kg/cm2)
SYSTEM WEIGHT: 5000 lbs.
DIMENSIONS (mm):
MAIN UNIT: 1400 W. x 1120 Dp. x 2690 H.
HYDRAULIC UNIT: 860 W. x 650 Dp. x 1100 H.