Top Seller
Fluke 437-II/Basic in United States
Location:
United States
Price:
$9,899 USD
Model:
437-II/Basic

Specifications

Condition:
used
Vpk:
1 Vpk to 1400 Vpk
Vrms:
1 V to 1000 V phase to neutral
Division:
Test and Measurement
Interfaces:
Screen, Software, PC card, USB
With 1mv/a:
5500 Apk
Launch date:
Jan-2012
With 1 mv/a:
maximum 2000 MW
Battery life:
Seven hours operating time per charge on Li-ion battery pack
Measurements:
Vrms, Vpk, VCF, Vrms1/2, Vfund, Amp (ac+dc), Apk, ACF, Amps1/2, Afund, Watts (VA, var), PF, kWh, Energy loss, Harmonics, Unbalance, Monitor, Inrush, Dips & Swells, Flicker, Transients
Vrms (ac+dc):
1 V to 1000 V phase to neutral
A crest factor:
1 to 10
Input channels:
4 (3 phase + neutral) dc-coupled
With 1 mv/a 1x:
5 A to 2000 A
With i430-flex:
8400 Apk
@ 50 hz nominal:
42.50 Hz to 57.50 Hz
@ 60 hz nominal:
51.00 Hz to 69.00 Hz
Instrument type:
Handheld
Operation modes:
Power quality analyzer, Energy analyzer, Scope, Energy loss calculator, Inverter efficiency, Meter, Trend recorder, Logger, Bar graph, Event capture, Power wave function, Mains signaling
With 1 mv/a 10x:
0.5 A to 200 A, ac only
@ 400 hz nominal:
340.0 Hz to 460.0 Hz
With i430-flex 2:
maximum 6000 MW
With i430-flex 1x:
5 A to 6000 A
With i430-flex 10x:
0.5 A to 600 A
Voltage crest factor:
1.0 > 2.8
Troubleshoot real-time:
Analyze the trends using the cursors and zoom tools
Power factor (cos j/dpf):
0 to 1
View graphs and generate reports:
With included analysis software
Kwh (kvah, kvarh), and energy loss:
Depends on clamp scaling and V nominal
Subcategory:
Power
Subcategory 2:
Analyzers

Description

Fluke 437-II/Basic 400 Hz, Three-Phase Power Quality and Energy Analyzer
The new 430 Series II Power Quality and Energy Analyzers offer the best in power quality analysis and introduce, for the first time ever, the ability to monetarily quantify energy losses.
The new Fluke 434, 435 and 437 Series II models help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems.
Additionally, the Fluke-patented energy loss algorithm, Unified Power Measurement, measures and quantifies energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.
Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp
PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses
Troubleshoot real-time: Analyze the trends using the cursors and zoom tools
Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance
Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places
Automatic Trending: Every measurement is always automatically recorded, without any set-up
System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard
Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals
View graphs and generate reports: With included analysis software
Battery life: Seven hours operating time per charge on Li-ion battery pack
437-II
specifications:
Vrms (ac+dc): 1 V to 1000 V phase to neutral
Vpk: 1 Vpk to 1400 Vpk
Voltage crest factor: 1.0 > 2.8
Vrms½: 1 V to 1000 V phase to neutral
Amps (ac + dc)
with i430-Flex 1x: 5 A to 6000 A
with i430-Flex 10x: 0.5 A to 600 A
with 1 mV/A 1x: 5 A to 2000 A
with 1 mV/A 10x: 0.5 A to 200 A, ac only
Apk
with i430-Flex: 8400 Apk
with 1mV/A: 5500 Apk
A crest factor: 1 to 10
Amps½
with i430-Flex 1x: 5 A to 6000 A
with i430-Flex 10x: 0.5 A to 600 A
with 1 mV/A 1x: 5 A to 2000 A
with 1 mV/A 10x: 0.5 A to 200 A, ac only
Afund
with i430-Flex 1x: 5 A to 6000 A
with i430-Flex 10x: 0.5 A to 600 A
with 1 mV/A 1x: 5 A to 2000 A
with 1 mV/A 10x: 0.5 A to 200 A, ac only
Hz
@ 50 Hz nominal: 42.50 Hz to 57.50 Hz
@ 60 Hz nominal: 51.00 Hz to 69.00 Hz
@ 400 Hz nominal: 340.0 Hz to 460.0 Hz
Watts (VA, var)
with i430-Flex: maximum 6000 MW
with 1 mV/A: maximum 2000 MW
Power factor (Cos j/DPF): 0 to 1
kWh (kVAh, kvarh), and energy loss: Depends on clamp scaling and V nominal