Top Seller
AEMC 3711 Clamp-On Ground Resistance
Elgin, IL


Condition info:


AEMC 3711 Features:
Simple and fast clamp-on operation - no leads, no auxiliary rods or spacing requirements. No need to disconnect neutral service
Direct reading of ground resistance from 0.01Ω to 1200Ω
Direct reading of continuity and ground loop resistance
Direct reading of ground leakage or phase current from 1mA to 30Arms
Jaw design with large 1.25" (32mm) window - accommodates up to 1000MCM cables
Auto-off for power management
CE Mark and UL approved
Rugged Lexan head and body construction resists breakage
Patented design
The Clamp-on Ground Resistance Tester Model 3711 measures ground rod and small grid resistance through any season, without the use of auxiliary ground rods.
Check Resistance on Single and Multiple Rods or Grids
Clamp-on Ground Resistance Testers are used in multi-grounded systems without disconnecting the ground under test. The Model 3711 simply clamps around the ground conductor or rod and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.