Top Seller
Associated Research 700A Dielectric Analyzer
Location:
Elgin, IL
Model:
700A

Specifications

Condition:
used
Accuracy:
±(2% of Setting + 5 volts)
Accuracy 2:
±(2% of setting + 2 counts)
Accuracy 6:
±1%
Accuracy 7:
±(0.1% + 0.05 sec.)
Accuracy 9:
±(2% of setting + 2 volts)
Resolution:
1 volt/steps
Accuracy 10:
±(2% of setting + 2 volts)
Accuracy 11:
±(0.1% + 0.05 sec.)
Resolution 2:
0.01 mA/steps
Resolution 3:
1 µA/steps
Resolution 5:
0.1 µA/steps
Resolution 6:
0.1 sec. increments
Resolution 8:
0.1 sec./steps
Output rating:
5 kVAC @ 40 mA, 6 kV DC @ 10 mA
Condition info:
Refurbished
Hi-limit range:
0 - 9999 MO (0 = off)
Lo-limit range:
1 - 9999 MO
Charge lo range:
0.000 - 3.500 µA or Auto Set
Dc output ripple:
=/< 4% Ripple RMS at 6 kV DC @ 3.5 mA, Resistive Load
Failure detector:
Audible and Visual
Ramp timer range:
AC 0.1 - 999.9 sec.
Delay timer range:
0, 0.5 - 999.9 sec. (0 = Constant)
Dwell timer range:
0, 0.3 - 999.9 sec. (0 = Constant)
Output regulation:
±(1% of setting + 5 volts) from no load to full load
Ac output waveform:
Sine Wave, Crest Factor = 1.3 - 1.5
Ramp hi (dc) range:
12 mA peak max., ON/OFF selectable
Arc detection range:
1 - 9
Hi-limit (ac) range:
0.00 - 40.00 mA
Hi-limit (dc) range:
0 - 9999 µA
Lo-limit (ac) range:
0.000 mA - 9.999 mA
Lo-limit (dc) range:
0.0 - 999.9 µA
Charge lo (dc) range:
0.0 - 350 µA or auto set
Output voltage range:
100 - 1000 VDC
Voltage display range:
0 - 1000 V
Max. ground resistance:
1O ±0.1O, fixed
Output frequency range:
60 Hz or 50 Hz, User Selectable
Output adjustment range:
0 - 5 kV AV or 0 - 6 kV DC
Ground continuity current:
DC 0.1 A ±0.01 A, fixed
Short circuit current max:
12 mA peak

Description

Specifications:
Input
Voltage 115/230 VAC ±15%, Single Phase, User selectable
Frequency 47 Hz - 63 Hz
Fuse 6.3 Amp 250 V Slo-Blo
Dielectric Withstand Test Mode
Output Rating: 5 kVAC @ 40 mA, 6 kV DC @ 10 mA
Output Adjustment Range: 0 - 5 kV AV or 0 - 6 kV DC
Resolution: 1 volt/steps
Accuracy: ±(2% of Setting + 5 volts)
Ramp Hi (DC) Range: 12 mA peak max., ON/OFF selectable
Charge Lo (DC) Range: 0.0 - 350 µA or auto set
Hi-Limit (AC) Range: 0.00 - 40.00 mA
Resolution: 0.01 mA/steps
Accuracy: ±(2% of setting + 2 counts)
Hi-Limit (DC) Range: 0 - 9999 µA
Resolution: 1 µA/steps
Accuracy: ±(2% of setting + 2 counts)
Lo-Limit (AC) Range: 0.000 mA - 9.999 mA
Resolution: 0.01 mA/steps
Accuracy: ±(2% of setting + 2 counts)
Lo-Limit (DC) Range: 0.0 - 999.9 µA
Resolution: 0.1 µA/steps
Accuracy: ±(2% of setting + 2 counts)
Arc Detection Range: 1 - 9
Failure Detector: Audible and Visual
DC Output Ripple: =/