Chroma Guardian 6100 Plus Medical
Elgin, IL
Guardian 6100 Plus


Condition info:
Four measurements mode:
Normal, Reverse, Single Fault Normal, Single Fault Reverse


Chroma Guardian 6100 Plus Features:
Five instruments in one: AC Hipot (hypot), DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
Twin-Port™ feature (Patented)
Programmable output voltage to 5kV AC and 6kV DC
Insulation resistance to 50GO/1000V DC
Ground bond up to 30A (Option up to 40A / 60A)
Open/Short check (OSC) function
ARC detection (Flashover)
Password Protected front panel lockout
Storage of 50 Tests Setups with 100 Steps per setup
Optional dynamic leakage current auto scanning
Standard RS-232 Interface
Standard GB KIT, SCANNER Interface
Optional GPIB Interface
Production and Compliance Testing of Medical Devices in Accordance with IEC, UL, CSA, EN and Other Standards such as IEC60601-1, UL2601-1, IEC950, UL544 and UL60950
ITE / consumer electronic safety testing
Transformer safety testing
Generator/motor safety testing
Component safety testing
Non-electronic safety testing
Appliance electrical safety testing
Medical equipment safety testing
The Guardian 6100 Plus is able to perform several dielectric tests in one unit including AC/DC Hipot, Insulation Resistance,Ground Bond, Open/Short Check and optional Leakage Current for compliance testing of IEC, UL, TUV, CSA, EN and other standards including IEC60601-1, UL2601-1, IEC950, UL544, UL60950. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The open / short check function (OSC) checks for an open connection or a DUT short during testing. Open connections may cause a bad DUT to test OK. Screening for shorts prevents damage to the equipment saving potential costs that may occur. These patented features are only available in safety products manufactured by Chroma.
The Guardian 6100 Plus Safety Analyzer’s leakage current scanners (A190308) can provide up to 20A input current capability for functional run testing as well as earth, enclosure, patient and line leakage current tests meeting IEC60601-1 compliance requirements.
Plugs into the Guardian 6100 Plus for Hipot, Line Leakage Auto Scanning
Five Different Kinds Human Body RC Network
Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
Up to 20A Line Input Current Capability
Build in A/D and Calibration Data Memory Easy to Install
Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test