Top Seller
Fluke 2625A Data Logger in
Elgin, IL


Condition info:
Resistance (Ω), resistance ranges:
300 Ω, 3 kΩ, 30 kΩ, 300 kΩ, 3 MΩ, 10 MΩ
Data loggers


NIST Calibration Pricing - $238.00
Fluke 2625A Features:
Channel Scanning: can be continuous scanning, scanning at an interval time, single scans, or triggered (internal or external) scans
Channel Monitoring: make measurements on a single channel and view these measurements on the display
Channel Scanning and Monitoring: view measurements made for the monitor channel while scanning of all active channels continues
Multi-Function Display: Left (numeric) display shows measurement readings; also used when setting numeric parameters; Right (alphanumeric) display used for numeric entries, channel number selection and display, status information, and operator prompts
Front-Panel Operation
Measurement Input Function and Range:
Volts dc (Vdc), dc voltage ranges 300 mV, 3 V, 30 V, 300 V
Volts ac (Vac), ac voltage ranges 300 mV, 3 V, 30 V, 300 V
Frequency (Hz), 15 Hz to 1 MHz
Resistance (Ω), resistance ranges: 300 Ω, 3 kΩ, 30 kΩ, 300 kΩ, 3 MΩ, 10 MΩ
Temperature Measurement: Thermocouple types J, K, E, T, N, R, S, and B, and Hoskins Engineering Co. type C are supported. Also, DIN/IEC 751 Platinum RTDs are supported
Totalize Events on the Totalizing Input
Alarm Limits and Digital Output Alarm Indication
4-Terminal Resistance Measurements (Channels 1 through 10 only)
RS-232 Computer Interface Operation
Measurement Rate Selection
Nonvolatile Memory: Storage of minimum, maximum, and most recent measurements for all scanned channels. Storage of Computer Interface setup, channel configurations, and calibration values. Storage of measurement data: storage for 2047 scans of up to 21 channels, representing up to 42,987 readings
RS-232 interface
90 to 264 Vac, 50 or 60 Hz operation; or 9.0 to 16 Vdc
The Fluke 2625A Data Acquisition Unit is a multi-channel data acquisition unit able to measure ac and dc voltages, temperature via thermocouples and RTDs, resistance, and frequency. It combines data logging memory with the features of the Data Acquisition Unit. It features 21 measurement channels, 8 digital input/output lines, a Totalizer input, and 4 alarm output lines. The Data Acquisition Unit is easily carried by hand and can be ac or dc powered. The user can choose communications with a host computer over an RS-232 interface.
The Fluke 2625A comes with a removable Universal Input Module that enables fast, convenient set-up and reconfiguration. Any combination of dc voltage, ac voltage, thermocouple, RTD, resistance, or frequency measurements can be connected to the input module without the need for additional signal conditioning. Thermocouple reference junction compensation is automatically performed by sensing the temperature of the input module's isothermal block.