Top Seller
Fluke 80i-600a AC Current Clamp
Location:
Elgin, IL
Model:
80i-600a

Specifications

Condition:
used
Output:
1 milliamp per ampere of input current (1mA/A)
Safety:
Protection Class Class II as defined in IEC 348 and ANSI C39.5
Division:
Electronic Test Equipment
Condition info:
Refurbished
Working voltage:
750V ac rms maximum
Input current range:
1A to 600A
Usable current range:
0.1A to 2000A, 5 seconds maximum above 600A
Maximum conductor size:
50.8 mm (2 inch.)
Shunt (load) resistance:
less than 12 Ω at multimeter input to maintain specified accuracy
Subcategory:
Probes
Subcategory 2:
Current probes

Description

The Model 80i-600A is a clamp-on ac current probe designed to extend the current measuring capability of an ac current meter to 600 amperes.
A clamp-on, 1000-turn coil designed into the probe allows measurements to be made without breaking the circuit under test. The coil serves as the secondary of a current transformer.
The current carrying conductor being measured serves as the primary. Because of a high efficiency, quadrature type of winding used, wire size and the position of the wire within the probe jaws does not effect accuracy.
Input Current Range: 1A to 600A
Output: 1 milliamp per ampere of input current (1mA/A)
Accuracy: ±2% of reading, 50 Hz to 1 kHz ±3% of reading (typical), 30 Hz to 50 Hz or 1 kHz to 10 kHz.
Working Voltage: 750V ac rms maximum
Maximum Conductor Size: 50.8 mm (2 inch.)
Shunt (load) Resistance: less than 12 Ω at multimeter input to maintain specified accuracy
Typical Bandwidth: -10% at 10 Hz and 50 kHz (1A, 400 Hz reference, excludes multimeter response)
Usable Current Range: 0.1A to 2000A, 5 seconds maximum above 600A
Safety: Protection Class Class II as defined in IEC 348 and ANSI C39.5