Top Seller
Keithley 2440-C SourceMeter w/ Contact
Location:
Elgin, IL
Model:
2440-C

Specifications

Condition:
used
Division:
Electronic Test Equipment
Condition info:
Refurbished
Colloids and surfaces b:
Biointerfaces
Circuit protection devices:
TVS, MOV, Fuses, etc.
Acs basic edition demonstrations:
Solar Cell Test
Nanotechnology online product tour:
Research to Production
Subcategory:
Meters

Description

Keithley 2440-C Features:
Completes the contact check verification and notification process in just 350µs to maintain high speed production throughput
Contact Check enabled on the instrument's front panel or remotely via the GPIB
50W continuous capacity to 5A
0.012% basic accuracy with 5-1/2-digit resolution
Built-in comparator for fast pass/fail testing
Digital I/O component handler interface
1000 readings/second at 4-1/2 digits
Product Intro
SourceMeter Family Product Brief
Product Tour
Model 2400 SourceMeter Instrument
Basic Edition of Keithley's Automated Characterization Suite
Product Demo
I/V Curve Tracing With the Series 2600 SourceMeters and LabTracer Software
ACS Basic Edition Demonstrations: Solar Cell Test
Automated Characterization System - Basic Edition Product Demonstration
Nanotechnology Online Product Tour: Research to Production
Support Videos
2400 Series - The Difference Between Real and Range Compliance
2400 Series - How To Use Saved Setups
2400 Series - How To Setup GPIB/RS-232 Communication
2400 Series - How To Setup A Fast Voltage Pulse
2400 Series - How To Restore Factory Defaults
2400 Series - How To Find The Serial # and Firmware Revision
2400 Series - How To Enable/Disable Source Autoclear
2400 Series - How To Enable/Disable the Beeper
2400 Series - How To Configure the Limits
2400 Series - How to Configure Output-off Modes
Series 2400 - How to Configure Local/Remote Sense
Model 2400 SourceMeter How-To Source 10V with 10 mA Compliance
Model 2400 SourceMeter How-To Source 1 mA
Model 2400 SourceMeter How-To Source 10 Volts
Model 2400 SourceMeter How-To Set Manual or Auto Ohms Mode
Model 2400 SourceMeter How-To Configure a Linear Voltage Sweep
Model 2400 SourceMeter How-To Enable / Disable the Interlock
Model 2400 SourceMeter How-To Configure a Custom/List Sweep
Application Note
Article
Brochure
Data Sheet
FAQ
Manual
Selector Guide
Specification
White Paper
Example Program
Firmware
Software
Software Driver
optional accessories
supplied accessories
system add ons/modules
calibration contracts
extended warranties
companion products
family products
Devices:
Discrete semiconductor devices
Passive devices
Transient suppression devices
ICs, RFICs, MMICs
Laser diodes, laser diode modules, LEDs, photodetectors
Circuit protection devices: TVS, MOV, Fuses, etc.
Airbags
Connectors, switches, relays
High brightness LEDs (DC and pulse)
Tests:
Leakage
Low voltage/resistances
LIV
IDDQ
I-V characterization
Isolation and trace resistance
Temperature coefficient
Forward voltage, reverse breakdown, leakage current
DC parametric test
DC power source
HIPOT
Photovoltaic cell efficiency (source and sink)
Dielectric withstanding
Academic research citing this product:
Total search results:
385
MORE >>
Title:
In-situ monitoring of the dielectric and electrostrictive properties of anodised thin films for biochip applications
Publication:
Colloids and Surfaces B: Biointerfaces
Authors:
J.-F. Vanhumbeeck and J. Proost
Title:
A study of room-temperature