Top Seller
1994 Magnaflux Model MD-1030S Multi-Directional
Location:
Warren, MI
Manufacturer:
Magnaflux
Model:
Model MD-1030S

Specifications

Condition:
used
Year:
1994
Stock number:
11590-00
Fob:
Warren, MI
Duty cycle:
½ Second On/10 Seconds Off
Maximum head opening:
29"
Air requirements(psi):
40 - 100
Approximate weight(lbs):
1625
Electrical requirements(v,hz,ph,a):
230/460, 60, 3, 150/75 Line

Description

Maximum Current Output 3000 Amp DC 2500 Amp AC, Maximun Head Opening 29", Built-In Demagnetizer, Separate Digital Ammeters
(1) USED Magnaflux, Model MD-1030S, Multi-Directional Magnetic
Particle Inspection Unit., Year 1994 S/N 94236
SPECIFICATIONS:
Magnetizing Intermittent Output Current(Amps): . . . . 3000 FW/HW DC
2500 AC
Duty Cycle: . . . . . . . . . . . . . . . . . . . . . .½ Second On/10 Seconds Off
Maximum Head Opening: . . . . . . . . . . . . . . . . 29"
Approximate Overall Dimensions(WxDxH): . . . . . . 72" x 32 x 58 ½"
Approximate Weight(Lbs): . . . . . . . . . . . . . . . 1625
Electrical Requirements(V,Hz,Ph,A): . . . . . . . . . .230/460, 60, 3, 150/75 Line
Air Requirements(PSI): . . . . . . . . . . . . . . . . 40 - 100
EQUIPPED WITH:
• Push Button Selectable for AC (Surface Flaws), HWDC or
FWDC (Near-Surface Defects)
• Separate Digital Ammeters for each energizing circuit
• Independent, Infinitely-Variable Current Controls
• Press-and Release Button for Quick 5 Second De-
Magnetization
• Adjustable Current Flow Alarms
• Frame, Hood and Fan with White Light
• Black Light
• Headstock and Tailstock
• Hip Bar Activated Magnetizing Shot
• Stainless Steel Tank, Spray Hose with Nozzle and Internal
Agitation System
FOB Warren, MI Cleaned, Serviced & Cycled
MGFLX2001