• 2100 Gallon Tycon Glass Lined Reactor #204561

        8000 liter tycon glass lined reactor, type ce8000, serial number 3513, rated -1/6 bar @ -60 to 200 degrees c internal; -1/6 bar @ -60 to 200 degrees c in the jacket. total volume 9,350 liters internal, 750 liters...

        No price
        West Windsor Township, NJ, USA
      • 3000 Gallon Tycon Glass Lined Tank #95715

          • Capacity: 3000 GALLON / 11370 LITER

          3,000 gal glass lined jkt vert tank. 7' dia x 9' str side, weld top, 10' clamp cone btm. mfd by tycon, sn 4369, nb #7, blt 1990. int rated 75 psi/full vac @ 400 deg f; jkt rated 100 psi/full vac @ 400 deg f. cs b...

          No price
          West Windsor Township, NJ, USA
        • 3000 Gallon Tycon Glass Lined Tank #95716

          • Manufacturer: Tycon
          • Capacity: 3000 GALLON / 11370 LITER

          3,000 gallon tycon glass lined tank, vertical with plate coil jacket, cone bottom. manufactured by tycon, serial number 4367, national board number 5,. internal rated 75 psi/full vac @ 400 deg f; panel coil jacke...

          No price
          West Windsor Township, NJ, USA
        • 317 Gallon Tycon Glass Lined Tank #214155

            • Capacity: 317 GALLON / 1200 LITER

            1200 liter tycon vertical glass lined tank, serial #4392, pressure -1/6 bar @ -10/200 degrees c, total volume 1355 ltr. 1.2m diameter x 924mm straight side, 2670mm overall heightl. openings include: top bottom ou...

            No price
            West Windsor Township, NJ, USA
          • 50 Gal Tycon Glass Lined Reactor 5945

            • Manufacturer: Tycon

              used tycon approximately 50 gal. glass lined reactor. rated 150 psi/full vacuum internal @ 450 deg. f. jacket rated 110 psi/full vacuum @ 450 deg. f. type 808 blue glass. bolted top. 2 hp, 460 volt, 1725 rpm wi...

              No price
              Red Bank, NJ, USA
            • 35 Gal Tycon Glass Lined Reactor 5959

              • Manufacturer: Tycon

                used tycon approximately 35 gal. glass lined reactor. rated 150 psi/full vacuum internal @ 450 deg. f. jacket rated 100 psi/full vacuum @ 450 deg. f. type 808 glass. clamp top. 1.5 hp drive with 3-blade retreat c...

                No price
                Red Bank, NJ, USA
              • 53 Gal Tycon Glass Lined Tank 6753

                • Manufacturer: Tycon
                • Capacity: 53 Gal

                used 53 gallon glass lined tycon portable vessel. internal rated 100 psi/fv @ 450 degrees f. jacket rated 100 psi/fv @ 450 degrees f. national board # 15. 30.56" diameter x 1' 1.78" length. fittings top: 6-...

                No price
                Red Bank, NJ, USA
              • 20 Gal Tycon Glass Lined Reactor (Body) 8423

                • Manufacturer: Tycon

                  unused tycon approximately 20 gallon glass lined reactor body. rated 100 psi/full vacuum internal and jacket @ 450°f. approximately 28" diameter x 12" straight side. clamped top. mounted on (3) legs.

                  No price
                  Red Bank, NJ, USA
                • 2000 30 GAL TYCON GLASS LINED REACTOR, 150/100#

                  • Manufacturer: Tycon Systems

                    used 30 gallon tycon glass lined reactor, rated 150 psi and full vacuum internal @ 450 f, jacket rated 100 psi and full vacuum @ 450 f, type 808 glass, clamp top, 1.5 hp drive with 3-blade retreat curve agitator,...

                    No price
                    Cleveland, OH, USA
                  • 2002 50 GAL TYCON GLASS LINED REACTOR, 150/110#

                    • Manufacturer: Tycon Systems

                      used 50 gallon tycon glass lined reactor, rated 150 psi and full vacuum internal @ 450 f, jacket rated 110 psi and full vacuum @ 450 f, type 808 blue glass, bolted top, 2 hp, 460 volt, 1725 rpm with 3-blade retre...

                      No price
                      Cleveland, OH, USA