7E Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-1000 ppm CO Maximum Overload: 2000 ppm CO Filter: To remove SOx/NOx and H2S Sensitivity: 0.10 ± 0.02 μA/ppm Response Time (T90): <...
Brescia, ItalyCD-300 Tecnosens
new
- Manufacturer: Tecnosens
The CD-300 product series offers NDIR modules for CO2 with current- or voltage-selectable output transmitters: field-selectable settings by the customer via jamper. Measurement Ranges: 0-2000 ppm, 0-3000 ppm, 0-5...
Brescia, ItalyS+4 2ECO Tecnosens
new
- Manufacturer: Tecnosens
Electrochemical carbon monoxide cell for air quality applications, home CO detectors, ventilation, and underground parking lots. Measurement Range 0 - 1000 ppm Output Signal 50 ± 20 nA / ppm Linearity Within ±5% ...
Brescia, Italy3SF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-2000 ppm CO Maximum Overload: 5000 ppm CO Filter: None Sensitivity: 0.10 ± 0.02 μA/ppm Resolution: 1 ppm (electronics dependant) R...
Brescia, ItalyGS+7NH3-1000 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 1000 ppm Typical Baseline Range (pure air) ±10 ppm NH3 equivalent Output Signal 8 ± 4 nA/ppm Linearity Linear Response Time, T90 <60 s Maximum Overload 1500 ppm Long-term Output Drift <20% per annum Rec...
Brescia, ItalyGS+7H2S Tecnosens
new
- Manufacturer: Tecnosens
Typical Baseline Range: <±1 ppm H2S equivalent Measurement Range: 0 - 200 ppm Output Signal: 370 ± 100 nA / ppm Linearity: Linear Repeatability: < ±1% H2S equivalent Response Time, T90: <40 s Maximum Overload: 10...
Brescia, ItalyGS+7CL2 Tecnosens
new
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1000 ± 300 nA / ppm Linearity: Linear Repeatability < ±2% Cl2 equivalent Response time, T90 <60 s Maximum Overload 250 ppm Long-term Output Drift <20% per annum Recommen...
Brescia, ItalyGS+4NH3-300 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 300 ppm Typical Baseline Range (pure air) ±2 ppm NH3 equivalent Output Signal 40 ± 15 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 500 ppm Long-term Output Drift <20% per annum Reco...
Brescia, Italy3NT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-100 ppm Sensitivity Range: 0.55 ± 0.11 μA/ppm Baseline Offset at 20°C: 0 to 3 ppm equivalent Bias Potential: +300 mV Linearity: linear Response Time at 20°C: < 10 seconds (t90) Long Term Sensit...
Brescia, Italy3HYT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1000ppm Sensitivity Range: 30 ± 10 nA/ppm Baseline Offset at 20°C: 0 to 15 ppm equivalent Bias Potential: Not required Linearity: Linear Response Time at 20°C: < 50 seconds (t90) Long Term Sens...
Brescia, ItalyFCX-MW-F Tecnosens
new
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-95% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyFCX-MEP2-F Tecnosens
new
- Manufacturer: Tecnosens
The board allows measurement of O2 concentration in the range 0.1-25% . Zirconium oxide technology has excellent stability over time, which avoids frequent calibration procedures and allows for particularly long ...
Brescia, ItalyGS+4NH3-100 Tecnosens
new
- Manufacturer: Tecnosens
Range 0 - 100 ppm Typical Baseline Range (pure air) ±1 ppm NH3 equivalent Output Signal 100 ± 30 nA/ppm Linearity Linear Response Time, T90 <40 s Maximum Overload 200 ppm Long-term Output Drift <20% per annum Rec...
Brescia, ItalyGS+4ETO Tecnosens
new
- Manufacturer: Tecnosens
Measurement Range 0 - 20 ppm Output Signal 1900 ± 600 nA / ppm Linearity: Linear Repeatability < ±2% ETO equivalent Response time, T90 <120 s Maximum Overload 100 ppm Long-term Output Drift <20% per annum Recomme...
Brescia, ItalyGS+4CO Tecnosens
new
- Manufacturer: Tecnosens
Electrochemical carbon monoxide cell with range 0-2000 ppm, manufactured by DD Scientific Suitable for industrial applications, especially for portable detectors. Range 0 - 2000 ppm Output Signal 70 ± 20nA/ppm Li...
Brescia, Italy