EXCHANGERS 112335
used
Used 437 Sq. Ft. Horizontal Utube Heat Exchanger. Mfg. by Fabsco Shell and Tube LLC in 2012. All 304L Stainless Steel. 18"/24" diameter x 16'0" F/F. Previous Service: AGR Rich Flash Gas Cooler.
Cleveland, TXEXCHANGERS 112292
used
Used 437 Sq. Ft. Horizontal Utube Heat Exchanger. Mfg. by Fabsco Shell and Tube LLC in 2012. All 304L Stainless Steel. 18"/24" diameter x 16'0" F/F. Previous Service: AGR Rich Flash Gas Cooler.
Cleveland, TXEXCHANGERS 113841
used
Used approximately 3480 sq. ft. 304 Stainless Steel shell & tube vertical heat exchanger. Mfg. by Harliss Specialties Corp in 1987. Shell SA515 Gr 70, 3' 1.25" diameter X 15' long. Maximum working pressure 75 ...
Cleveland, TXEXCHANGERS 114249
used
Previously Utilized in an API Facility. Used Condenser for K-2407 / R-2408; 92 sq. ft. Shell & Tube horizontal Exchanger. Mfg. by Kam Thermal. 316 Stainless Steel tubes MOC. 90 psi.
Cleveland, TXEXCHANGERS 113764
used
Used 424 sq. ft. Horizontal Exchanger. Mfg. by Perry Products in 1999. 14" diameter. Shell: Carbon Steel, 100 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 100 psi @ 350 deg. F. With expansion joint.
Cleveland, TXEXCHANGERS 113157
used
Used approximately 150 sq. ft. Southern heat exchanger. Approximately 12" diameter X 6' long shell. 3/4" stainless steel tubes. Shell side 50 FV @ 250 degrees F. Tube side 50 psi @ 250 degrees F. Horizontal...
Cleveland, TXEXCHANGERS 112798
used
Used 12,580 sq. ft. plate exchanger. Mfg. by Alfa Laval, Inc. in 2012. Model #TL35-BFD. Previous Service: Venturi scrubber pump around cooler. (2)14" inlets & (2) 14" outlets. (811) plates x .02" thick.
Cleveland, TXEXCHANGERS 114590
used
Unused 377.9 sq. ft. plate exchanger. Mfg. by Alfa Laval in 2023. MAWP: 150/FV psig @ 356 deg. F. MDMT: 150/FV psig @ -20 deg. F. Model T21-MFG. A-Dim 183 mm with (40) 0.6 mm plates.
Cleveland, TXEXCHANGERS 95061
used
- Manufacturer: SWECOMEX
KELLOGG #108-C UNUSED BFW EXCHANGER; BUILT FOR 1500 TPD KELLOGG AMMONIA PLANT; MFG. BY SWECOMEX IN 1988; 999MM X 6035 MM; 335M2; SHELL: 10.5 KG/CM @ 280 DEG. C.; TUBES 10.5 KG/CM @ 93 DEG. C.;
Cleveland, TXEXCHANGERS 113770
used
Used 458 sq. ft. Vertical Exchanger. Mfg. by Doyle & Roth in 1998. 30" diameter x 12'0" F/F. Shell: Carbon Steel, FV/130 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 100 psi @ 350 deg. F.
Cleveland, TXEXCHANGERS 113771
used
Used 745 sq. ft. Horizontal Exchanger. Mfg. by Manning & Lewis in 1999. 30" diameter x 12'0" F/F. Shell: Carbon Steel, 140 psi @ 350 deg. F. Tubes: 304L Stainless Steel, 110 psi @ 350 deg. F. (633) 3/4" O.D. x 16...
Cleveland, TXEXCHANGERS 113775
used
Used 375 sq. ft. Exchanger. Mfg. by Gaspar in 2005. 14" diameter x 20'0" F/F. Shell: Carbon Steel, FV/123 psi @ 350 deg. F. Tubes: Hastelloy C 276, FV/123 psi @ 350 deg. F. (96) 3/4" O.D. x .065".
Cleveland, TXEXCHANGERS 102481
used
- Manufacturer: VRV SPA
MFG. BY VRV.SPA IN 2000; 8200MM LENGTH; 1100MM WIDTH; 1000MM HEIGHT; 97 SQM 316L (2RE69) TUBES CS (ASTM A51GR60) SHELL VERTICAL HEAT EXCHANGER/EVAPORATOR; TUBE PRESSURE 14 BAR @ 150/170 DEG. C.; SHELL 25 BAR ...
Cleveland, TXEXCHANGERS 113777
used
Used 560 sq. ft. Vertical Exchanger. Mfg. by Gaspar in 2005. 18" diameter x 16'0" F/F. Shell: Carbon Steel, 123 psi @ 350 deg. F. Tubes: Hastelloy C 276, 123 psi @ 350 deg. F. (178) 3/4" O.D. x .065"., Heads are ...
Cleveland, TXEXCHANGERS 114443
used
Used 270 sq. ft. solvent recovery still horizontal exchanger. Mfg. by Perry Products. 8'0" F/F. (206)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 334 deg. F. Tubes 304 stainless steel, 44FV psi @ 334 de...