Tokyo Rika Machine CA-351H
used
- Manufacturer: Tokyo Rika
Cooling capacity: 3700/4200Kcal/h Heat exchange tank capacity: 75L
Hiroshima, JapanHitachi HC-F300GXY
used
- Manufacturer: Hitachi
Freezing capacity: 1055kw 300USRT Cold water inlet temperature: 12 ° C Cold water outlet temperature: 7 ° C Refrigerant: R-134a
Hiroshima, Japan2000 Hitachi Air Conditioning System RCUJ 2650 W
used
- Manufacturer: Hitachi
Legal freezing capacity: 32.3 / 39.0 tons Cooling capacity: 236/265 kW Cold water temperature: input 12 ° C out 7 ° C Amount of cold water: 40.6 / 45.6 m³ / h Cooling water temperature: 30/35 ℃ Cooling water quan...
Hiroshima, JapanKowa Kogyosho KGO-1000
used
- Manufacturer: Kowa Kogyosho
1-stage, 2-type division Power: 2.2Kw 200V | Purchasing area: 60Hz | Material: Wetted part SUS | Quantity saved: 1
Hiroshima, Japan2004 Dalton C701C
used
- Manufacturer: Dalton
Frame diameter: φ700, 1 stage, 1 type Cassette type screen Formerly used as ultrasonic sifting machine Vibrating sifting machine with the equipment removed Used as a Ultrasonic terminal required separately (hand ...
Hiroshima, Japan- Hiroshima, Japan
Seishin company P-60
used
- Manufacturer: Seishin
Sonic type screen machine, net 75μ Material: SUS | Quantity saved: One
Hiroshima, JapanMultitubular heat exchanger
used
2 passes. Since there is no documentation, the heat transfer area cannot be determined without removing the mirror and investigating the diameter x number x length of tubes.
Hiroshima, JapanMulti-tube heat exchanger, vertical type
used
Heat transfer area: 4.7 m2 Tube: inner diameter 30mm, length 1240mm Number of tubes: 40 tubes, 400φ, single mirror SUS Heat transfer area: 4.7 m2
Hiroshima, Japan1998 Hisaka Manufacturing UX-016A-KNJR-8
used
- Manufacturer: Hisaka
Heat transfer area: 0.5m2 Material: Wetted part SUS | Quantity saved: Two
Hiroshima, Japan1991 Carbon capacitor
used
Heat resistance temperature: 360°C Withstand pressure: 0.5MPa(75PSIG) Heat Transfer Area: Unknown (Approx. 10㎡ based on size)
Hiroshima, Japan[Carbon capacitor No model
used
Heat transfer area: Unknown (about 10 square meters based on the size). Other: Unknown (because there is no nameplate).
Hiroshima, JapanSSC RC456SK-42-9
used
- Manufacturer: SEC
Cubic type Heat transfer area: 1.12 m2 Material: carbon | Quantity saved: One
Hiroshima, Japan2007 Seiko Kako FTF 803-LH2-S
used
- Manufacturer: Seiko Kakoko
Air volume: 1100 m3/min Static pressure: 2.4 kpa Suction port diameter: 1200 mm Restricted gas temperature: 80°C
Hiroshima, Japan1985 Muto Electric Corporation MLD-1003 (300) M
used
- Manufacturer: Muto Electric
11kw, 12m3/min Airflow: 12m3/min Static pressure: -1000mmAq
Hiroshima, Japan