- Sint-Niklaas, Belgium
Calibration Vibrating Table and Sieve Shaker
used
Calibration Vibrating Table Control of Fraquency and Falling Height wiè certificate after payment
Sint-Niklaas, Belgium- Sint-Niklaas, Belgium
- Sint-Niklaas, Belgium
- Sint-Niklaas, Belgium
- Sint-Niklaas, Belgium
- Sint-Niklaas, Belgium
Lightweight penetrometer ZLR-10
used
Lightweight penetrometer ZLR-10 according to DIN EN ISO 22476-2:2005 (DPL) (before DIN 4094) and TP BF-StB Teil B 15.1(DPL-5) > includes: 1 x Pile driver (10 kg) 1 x Anvil 1 x Guide bar with handle 6 x Plumb with...
Sint-Niklaas, BelgiumDigital Crack width gauge with data connection
used
digital gap meter with wireless data connection sensor range +/- 80 mm d = 0,003mm incl.met air temperature data logger wireless data connection or USB connection The Wireless Crack Movement Recorder provides con...
Sint-Niklaas, BelgiumA083: Aggregate crushing value apparatus dia.75mm
used
Aggregate crushing value apparatus dia.75mm Standard: comparable to BS 812:110 Comprising 75 mm nominal diameter steel cylinder, plunger, base plate, tamping rod and measure 57 mm diameter x 90 mm deep. Used for ...
Sint-Niklaas, BelgiumZORN LAB 3.1 (5kg-150mm)
used
- Manufacturer: ZORN
ZORN LAB 3.1 (5kg -150 mm) incl. Proctor mold collar 6 inch ? Integrated Wi-Fi module for wireless LWD data transfer to smartphone, tablet or personal computer ? Load device with 5 kg drop weight, impact load 3.5...
Sint-Niklaas, BelgiumA081-01 : Lightweight aggregates crushing resistance
used
Lightweight aggregates crushing resistance Standard : EN 13055-1 METHOD 1 Apparatus for the determination of the crushing resistance of lightweight aggregates having diameter from 4 to 22 mm, and a volumic mass o...
Sint-Niklaas, BelgiumB024 : Permeameter
used
Permeameter Mainly used in situ to perform and to check the permeability and drainage on road carpets, concrete pavements, tamped earth etc. The test consists in filling the cylinder with water, after ermetically...
Sint-Niklaas, BelgiumCalibration Proctor Mould Small diam 100
used
- Manufacturer: Proctor
Calibration of a Proctor Mould: diameter and height The calibration/testing services offered in this quotation are performed by European Lab Services site Sint-Niklaas. European Lab Services is accredited accordi...
Sint-Niklaas, BelgiumCalibration Pull off Tester
used
Calibration for a Pull off tester with one channel under ISO17025 accreditation 327-CAL The calibration/testing services offered in this quotation are performed by European Lab Services site Sint-Niklaas. Europea...
Sint-Niklaas, Belgium