- Trusted Seller
Carbon Steel HEAT WM550 Hot Oil Boiler - IPP# 239471
used
- Manufacturer: HEAT
480 V hot oil 3 ph 60 Hz top mounted expansion tank 48" W x 32" D x 72" H.
Princeton Junction, NJ - Trusted Seller
Carbon Steel HEAT WM550 Hot Oil Boiler - IPP# 239470
used
- Manufacturer: HEAT
27 kw hot oil 480 V, 3 ph 60 Hz top mounted expansion tank 48" W x 32" D x 72" H
Princeton Junction, NJ - Trusted Seller
Hot Oil Boiler Carbon Steel - IPP# 234972
used
- Manufacturer: Chromalox
Rated for 40 kW at 460 Volts, 3 phase, 60 Hz Part # 101-120863-018 60 GPM belt driven pump with 5 hp. motor 2" connections, NEMA enclosure with controls.
Princeton Junction, NJ - Trusted Seller
Hot Oil Boiler - IPP# 228337
used
- Manufacturer: Fulton
Thermal fluid heater Burner motor 1.5 HP. EX proof controls
Princeton Junction, NJ - Trusted Seller
Hot Oil Boiler - IPP# 218660
used
- Manufacturer: H.E.A.T.
Electric hot oil heater Heat output: 1,229,194 BTU/hr Complete system with (2) vertical 180 KW electric heaters, 3/60/480 volt, Serial Number J600-1 & 2 circulating pumps
Princeton Junction, NJ - Trusted Seller
Stainless Steel 304 Dillon Boiler Services Co. Inc Tank - IPP# 246461
used
- Manufacturer: Dillon Boiler Services Co. Inc
PFN3 knock out pot for Cogiem Filter
Princeton Junction, NJ - Trusted Seller
Stainless Steel 316 Missouri Boiler and Tank Co Batch-Type Agitated Reactor - IPP# 235924
used
- Manufacturer: Missouri
Princeton Junction, NJ - Trusted Seller
Stainless Steel 304 Missouri Boiler and Tank Co Shell and Tube Heat Exchanger - IPP# 246719
used
- Manufacturer: Missouri
Princeton Junction, NJ - Trusted Seller
IPP# 600658, Power Plant - 3.2 MW Cogeneration Plant (CHP) Power Plant
used
3.2 MW Gas Fired Co-Generation combined heat and power plant. With (4) 800 KW Caterpillar natural gas-fired, after-cooled, lean burn 3516 90 LE reciprocating engine generator sets each rated at 820kWe output at 4...
Princeton Junction, NJ - Trusted Seller
IPP# 603019, 112 MW Combined Cycle and Cogeneration Power Plant
used
112 MW Combined cycle and Cogeneration 1 on 1 power train configuration 1 Gas turbine, 1 Steam turbine, 1 HRSG 2 x GSUT 1 x 115 kV / 23 kV transformer 1 x 115 kV/ 6.9 kV Aux transformer 2 x 6.9 kV/ 400V Aux trans...
Princeton Junction, NJ - Trusted Seller
Siemens HG40 Steam Turbine - IPP# 94663
used
- Manufacturer: Siemens
- Model: HG40
back pressure turbine, steam consumption 13.55 lb/BHP/hr, inlet temp normal 940 deg F, inlet temp max 965 deg F, Total flow 148200 lbs/hr.
Princeton Junction, NJ - Trusted Seller
Carbon Steel GHH GTHR7/130 Gas Turbine - IPP# 216227
used
- Manufacturer: GHH
Designed for Nitric Acid Tailgas Used to drive compressor IPP # 216225 & 216226 Flow is 347-642 #/Hr. RPM is 5733 Inlet ; 130 psi at 1150 degrees F, Exhaust psi is 15 psi Maximum continuous speed is 6020. Max. op...
Princeton Junction, NJ - Trusted Seller
Starter And Switch Gear Electrical - IPP# 222969
used
- Manufacturer: Siemen's
S 7 controls for hydrogenation system
Princeton Junction, NJ - Trusted Seller
Contactor Column 457.2 mm (18 in) Stainless Steel 316 - IPP# 33884
used
- Manufacturer: Kuhni
extraction column Has 1-8' section; (2) 36" long heads Unit has top entering agit Mech seal on shaft (no motor)
Princeton Junction, NJ - Trusted Seller
Stainless Steel 316 Kleiser und Losch Gmbh Contactor Column - IPP# 212764
used
- Manufacturer: Kleiser und Losch Gmbh
column chamber in (4) bolted sections, approx (20) blades on shaft water cooled mechanical seals (3) s/steel centrifugal pumps
Princeton Junction, NJ California Instruments 6000LS Power Supply
used
- Manufacturer: California Instruments
- Model: 6000LS
Good condition California Instruments 6000LS Power Supplies. Located in Ireland and other countries. Click request price for more information.
Ireland