NO2 3E 50 Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-50 ppm Sensitivity Range: 200 nA/ppm ± 40 nA/ppm (negative signal) Zero Current at 20°C: < ± 20 nA Resolution at 20°C: < 0.1 ppm Bias Potential: 0 mV Linearity: < 5% full scale Response Time at...
Brescia, ItalyH-250-12V Tecnosens
new
- Manufacturer: Tecnosens
The H-250 series consists of the most compact NDIR modules for measuring high CO2 concentrations on the market. Due to its stability, built-in temperature change compensation as well as easy handling of the modul...
Brescia, ItalyNH3 3E 500 SE Tecnosens
new
- Manufacturer: Tecnosens
Amperometric 3 electrode sensor cell Measuring Range: 0-500ppm Sensitivity Range: 35nA/ppm ± 15nA/ppm Zero Current at 20°C: <± 100nA, typically 40nA Bias Potential: 0 mV Linearity: <10% full scale Response Time a...
Brescia, ItalyNH3 3E 100 SE Tecnosens
new
- Manufacturer: Tecnosens
Amperometric 3 electrode sensor cell Measuring Range: 0-100 ppm Sensitivity Range: 130 nA/ppm ± 30 nA/ppm Zero Current at 20°C: < ± 100 nA Resolution at 20°C: <1 ppm Bias Potential: 0 mV Linearity: <10% full scal...
Brescia, ItalyHCN 3E 30 F Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0 - 30 ppm Sensitivity Range: 60 nA/ ppm ± 15 nA/ ppm Zero Current at 20°C: < ± 15 nA Resolution at 20°C: < 0.2 ppm Bias Potential: 0mV Linearity: < 5% full scale Response Time at 20°C: t50 < 25 ...
Brescia, ItalyHCN 2E 30 F Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0 - 30 ppm Sensitivity Range: 30 nA/ ppm ± 15 nA/ ppm Zero Current at 20°C: < ± 5 nA Resolution at 20°C: < 0.2 ppm Bias Potential: not required Linearity: < 5% full scale Response Time at 20°C t5...
Brescia, ItalyF2 3E 1 Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1 ppm Sensitivity Range: 100 nA/ppm ± 300 nA/ppm (negative current) Zero Current at 20°C: < ± 20 nA Resolution at 20°C: < 0.02 ppm Bias Potential: 0 mV Linearity: < 5% full scale Response Time ...
Brescia, ItalyB2H6 3E 1 LT Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-1ppm Sensitivity Range: 2200 ± 500 nA/ppm Baseline Offset at 20°C: < ± 20 nA Bias Potential: 0 mV Linearity: < 10% full scale Response Time at 20°C: < 30 seconds (t90) Long Term Sensitivity Dri...
Brescia, ItalyA3STF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 4-electrode electrochemical Measurement Range: 0-10ppm SO2 Maximum Overload: 100 ppm Filter: To remove H2S and HCl Sensitivity: 0.60 ± 0.12 μA/ppm Response Time (T90): < 40 second...
Brescia, ItalyA3CO Tecnosens
new
- Manufacturer: Tecnosens
Nominal Range: 0-500ppm Maximum Overload: 1000ppm Expected Operating Life: Two years Output Signal: 0.2 ± 0.04 μA/ppm Resolution: 100ppb Temperature Range: -20°C to +50°C Pressure Range: Atmospheric ± 10% Pressur...
Brescia, Italy7NDH Tecnosens
new
- Manufacturer: Tecnosens
Measuring Range: 0-20 ppm Sensitivity Range: 1.40 ± 0.30 μA/ppm Baseline Offset at 20°C: -0.1 to +0.1 ppm NO2 equivalent Bias Potential: not required Linearity: linear Response Time: < 40 seconds (t90) Long Term ...
Brescia, Italy7ETO Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-20 ppm C2H4O Maximum Overload: 100 ppm C2H4O Filter: None Sensitivity: 2.25 ± 0.65 μA/ppm Response Time (T90): <140 Seconds Baseli...
Brescia, Italy7EF Tecnosens
new
- Manufacturer: Tecnosens
MEASUREMENT Operating Principle: 3-electrode electrochemical Measurement Range: 0-10000 ppm CO Maximum Overload: 2000 ppm CO Filter: To remove SOx/NOx and H2S Sensitivity: 0.10 ± 0.02 μA/ppm Response Time (T90) 7...
Brescia, ItalyCDM7162-C00 Tecnosens
new
- Manufacturer: Tecnosens
The CDM7162 is a dual beam NDIR module developed for air quality control systems, ventilation systems, air conditioning systems, etc. The module comes calibrated and with I2C and UART interfaces. From a size pers...
Brescia, ItalyCD-200 Tecnosens
new
- Manufacturer: Tecnosens
The CD-200 product series offers NDIR modules for CO2 with current- or voltage-selectable output transmitters: field-selectable settings by the customer. Measurement Ranges: 0-2000 ppm, 0-5000 ppm and 0-10000 ppm...