Anritsu MA9722A
used
- Manufacturer: Anritsu
The Sensor is a compact handy power meter with a measurement level as wide as other more expensive instruments. Each can be calibrated for three common wavelengths so absolute optical power can be read directly. ...
Webster, MAAnritsu ML93B
used
- Manufacturer: Anritsu
- Model: ML93
The Anritsu ML93B Optical Power Meter Measures wavelengths from 0.38 to 1.8 micrometers over a wide dynamic range of -90 to +10 dBm. It requires one of seven power sensors, which all provide 0.001 dB resolution. ...
Webster, MAAnritsu ML2408A
used
- Manufacturer: Anritsu
- Model: ML2408A
This power meter is the ideal solution for accurate measurements of IS-95 signals, giving average, peak and crest readings Pulses down to 1µs can be captured and displayed in graphical mode thanks to the 0.6µs ri...
Webster, MA- Webster, MA
Advantest Q82233
used
- Manufacturer: Advantest
- Model: Q82233
This Optical Sensor has a long wave and high sensitivity. It has FC,MU,SC,ST connector type and maximum power of 0.01Watts.
Webster, MARohde & Schwarz ESVS-30
used
- Manufacturer: Rohde & Schwarz
- Model: ESVS
Form Factor Benchtop Test Standard(s) ANSI,C63.4,EN,CISPR,VDE0876 Minimum Frequency 20 MHz Maximum Frequency 1 GHz Input Impedance 50 Ohm Frequency Accuracy 0.000000000000003 % Minimum Sweep Time 50 ms Ma...
Webster, MA- Webster, MA
Advantest Q8326
used
- Manufacturer: Advantest
- Model: Q8326
Operating Temperature: +10 to +40°C, Relative humidity: 85% or less Storage Temperature: -10 to +50°C Relative humidity: 90% or less
Webster, MA- Webster, MA
Tektronix 27120B
used
- Manufacturer: Tektronix
This EMI Test System is only as good as the software that runs it. The new EMI Precompliance Test Software strikes a proper balance between powerful features and ease of use. For the new user, there's a HELP Wiza...
Webster, MARohde & Schwarz NRVZ53
used
- Manufacturer: Rohde & Schwarz
This Sensor measures the average power irrespective of the waveform and therefore are also suitable for spread spectrum, IS-95 CDMA and W-CDMA measurements, irrespective of the peak to average power ratio of the ...
Webster, MARohde & Schwarz NRVZ202
used
- Manufacturer: Rohde & Schwarz
This Power sensor is based on diode detectors with 20dB attenuator. Measure true RMS power from 10nW to 1mW. For sinewave signals, the measurement range extends up to 500mW. Shorter measurement times than thrmoco...
Webster, MA- Webster, MA
Anritsu MP716A
used
- Manufacturer: Anritsu
- Model: MP716A
This Power sensor has a maximum input power of 22dBm. This is required for millimeter waveband. This unit commit linearity error of ±3% in only +10 to +20dBm range. This unit has a dimensions and mass of 52ø x 78...
Webster, MA- Webster, MA