EXCHANGERS 112799
used
Used 12,580 sq. ft. plate exchanger. Mfg. by Alfa Laval, Inc. in 2012. Model #TL35-BFD. Previous Service: Venturi scrubber pump around cooler. (2)14" inlets & (2) 14" outlets. (811) plates x .02" thick. NBRP Clip...
Cleveland, TXEXCHANGERS 113508
used
Used 1004 Sq. Ft. Vertical Heat Exchanger. Mfg. by Metler in 2012. 28" diameter x 7'0" F/F. Shell: Carbon Steel, 150 psi @ 302 deg. F. Tubes: Stainless Steel, (731) 3/4" O.D. x 16 BWG, 116FV @ 302 deg. F. Heads: ...
Cleveland, TXEXCHANGERS 113042
used
Used 2200 Sq. ft. Zirconium Exchanger. Mfg. by Apex in 2012. Apex Model # Zr-28-288-2200-CS. 28.75" OD. 25'6.75" O.A.L. **Note: Requires one head, the exchanger was directly piped to tubesheet.
Cleveland, TXEXCHANGERS 114544
used
Used 603 sq. ft. vertical exchanger. Mfg. by Perry Products in 2012. 16" diameter x 16'0" F/F. Shell, tubes and heads 304 stainless steel. 75FV @ 300 deg. F. shell. 75FV @ 300 deg. F. tubes. (192) 3/4" O.D. x 18 GA.
Cleveland, TXEXCHANGERS 113369
used
Used 7 sq. ft. Vertical Plate Exchanger, Mfg by Alfa Laval in 2015. .60 MM Plate Thickness, Model #TS6-MFG. EPDMP Clip On Plate Exchanger Gaskets. Previous Service: Desorbent Water Feed Heater.
Cleveland, TXEXCHANGERS 114546
used
Used 75 sq. ft. vertical exchanger. Mfg. by Yula in 2018. 6" diameter x 8'0" F/F. Shell is 304L stainless steel, tubes and heads are 316L stainless steel. 150FV @ 400 deg. F. shell. 150FV @ 400 deg. F. tubes. (...
Cleveland, TXEXCHANGERS 113351
used
Used 22 sq. ft. Vertical Plate/Block Exchanger, Mfg by Alfa Laval in 2015. (90) Plates Compabloc, Model CP15-H-40. Type Plate/Block. 2" Hot Outlet, 4" Hot Inlet, 4" Cold Outlet, 4" Cold Inlet. Previous Service: H...
Cleveland, TXEXCHANGERS 113352
used
Used 7.9 sq. ft. Vertical Plate/Block Exchanger, Mfg by Alfa Laval in 2015. (30) Plates Compabloc, Model CP15-H-30. Type Plate/Block. 4" Hot Inlet, 2" Hot Outlet, 1" Cold Inlet, 1" Cold Outlet. Previous Service: ...
Cleveland, TXEXCHANGERS 114124
used
Used 832 Sq Ft Vertical Shell and Tube heat exchanger. Manufactured by Rubicon in 1998. Carbon Steel Shell rated 200 PSI @ 450 deg. F. Hastelloy C276 Tubes rated 50 PSI/FV @ 350 deg. F. 222-1"OD x 16 BWG tubes 14...
Cleveland, TXEXCHANGERS 114445
used
Used 200 sq. ft. recovery still horizontal exchanger. Mfg. by Perry Products in 1991. 8'0" F/F. (153)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV psi @ 300 de...
Cleveland, TXEXCHANGERS 114439
used
Used 120 sq. ft. horizontal exchanger. Mfg. by Perry Products. 10" diameter x 8'0" F/F. (121)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV psi @ 300 deg. F. He...
Cleveland, TXEXCHANGERS 114442
used
Used 162 sq. ft. dryer horizontal exchanger. Mfg. by Perry Products. 12" diameter x 6'0" F/F. (165)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV psi @ 300 deg....
Cleveland, TXEXCHANGERS 114440
used
Used 118 sq. ft. concentration vessel horizontal exchanger. Mfg. by Perry Products. 10" diameter x 8'0" F/F. (121)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV...
Cleveland, TXEXCHANGERS 113207
used
Used 75 Estimated Sq. Ft. 304L Stainless Steel Vertical Plate Heat Exchanger. Mfg. by APV in 2015. With Carbon Steel Frame and 304L Stainless Steel Plates. Model #M-10. Rated mawp FV/150 psi @ 329 deg. F. mdmt -...
Cleveland, TXEXCHANGERS 114437
used
Used 166 sq. ft. ring closure reactor horizontal exchanger. Mfg. by Perry Products. 12" diameter x 8'0" F/F. (127)-5/8"o.d. x 18 ga. Shell 304 stainless steel, 85 psi @ 300 deg. F. Tubes 304 stainless steel, 35FV...
Cleveland, TX